2015 Trane Airhandler Checked and tightened all electrical connections Did not change filter at this time Drain was clear and draining at this time Heatstrips were functional and within manufacture range Blower Motor and wheel have heavy dust, dirt and Biological growth Evaporator coil has heavy dust, dirt and biological growth 2015 Trane Heatpump Checked and tightened all electrical connections Dual run cap is just outside the manufacture tolerance Disconnect is not functional and is jumpered on the inside with exposed wires on the outside Primary electrical unit was acceptable Defrost board was acceptable Defrost is functional Refrigerant levels were acceptable at this time System has 2 filter driers in refrigerant system could be causing restrictions in refrigeration Fan blades and motor were acceptable Condenser coils were acceptable Cleared debris from the bottom of the unit Washed condenser coils from the inside out Recommended coil cleaning, blower cleanin