Performed evaluation Upon arrival system cooling was off - Fan on Homeowner concern is water leaking to bottom bathroom - closet unit System delta 6 Indoor coil has massive build blocking airflow and causing water to drip underneath unit Indoor unit has high dirt/biological growth invading the units mechanical and electrical components Indoor blower motor fan has high build - motor stress Primary trap has small clog but cannot accept excess water flow Outdoor unit reccomendations - Out of tolerance dual run capacitor - primary electrical control unit gashing/burn - system has over manufacturer amperage start (soft start kit) Indoor unit reccomendations -cut/pull/clean coil -blower wheel clean -IAQ200 UV -drain clear/microbial treatment strip Due to level of build on indoor coil - refrigerant is not calculated - airflow affecting unit performance - system is likely to need refrigerant System cooling left off at exit - Fan on Scheduled comfort advisor Today 09/09/25 3pm-5pm