Upon arrival homeowner expressed concern over system performance and air flow Performed evaluation Washed condensor, replaced filter and tightened connections Delta 17 Previous homeowners added 2 supplies to existing system for garage and near room that is not rated for current tonage Reccomended Duct seal on supply on both ducts Reccomended soft start due to 109 starting amps Reccomended insulation due to very low levels inside attic - estimate for higher insulation levels on different estimate Reccomended Capacitor due to very low manufacturer rated readings When new coil and condenser were installed before new homeowner arrived - piston sizing is in question with higher than normal reading of refrigerant - once the correct environment and repairs are made system performance with home balance will change Added home and budget protection plan System left on cool at exit
On arrival system running and cooling producing 20 degrees delta. Indoor unit passed all electrical testing but uv bulb was off on arrival. It turned back on when power was cycled to the unit but is out of tolerance and ready to be replaced. Outdoor unit passed all testing but compressor overamped on start up. Recommended a compressor saver kit to reduce wear and tear to compressor by reducing amp draw on start up to under manufacture red line.
08/31/24 TS- installed new 40gal gas waterheater AO Smith. Customer supplied drain pan and gas flex line. I reused waterline connections and vent hood. Old waterheater didn't have a gas sediment trap or drain pan. New unit has been updated
08/30/24 TS- over the phone the customer would like to move forward first thing Tomorrow morning for a customer supplied waterheater
08/30/24 TS- multiple quotes on installing a new gas waterheater. Water supply lines need to be replaced. Water shutoff works but needs to be updated. Gas line needs a sediment trap and a new shutoff valve. Waterheater is on a stand but there's no pan.
System down on arrival Original capacitor not in tolerance at 6 of 45 System has 17 delta after capacitor replacement System left in cooling at exit