Arrived for service eval Dual run cap failed Replaced Motors running fine Compressor exceeding LRA at start and should have a start kit installed to help compressor start correctly and work with generator Slight gap in the plenum/coil connection that leaks air into the attic Reseal needed to prevent efficiency loss Biological growth in the supply plenum. UV system recommended to clean the system and airflow of the house Homeowner has an appointment to get to and will review the recommendations and get back with us on his decision.
Found a loose connection at the furnace preventing it from starting. After tightening the connection the system fired up and is operating as it should.
Painted flue pipe. And straightened it out.
Install 24 hz propane gas use current filtration includes code kit
Arrived for system down R22 refrigerant low System has build up on coil - ducts Reccomended system replacement Comfort advisor scheduled 6/26 at 5-7pm Recommended compressor saver kit and upgraded airfilter System left on off due to high water condensation affecting floor
Upon servicing system. Unit was not allowing compressor and outdoor motor to come on. Checked capacitor and it was dead. Installed new capacitor. Compressor was not running very good and saturation temps were nowhere near where I would expect them to be. Checked refrigerant. Home owner wants to replace complete system.