for logan, oh

Rated 2.0 out of 5 stars based on 1 customer reviews

Late and set off a fire alarm at midnight

The technicians arrived almost an hour after the appointment time, then took almost an hour to get started. Two hours in they set off the fire alarm, at midnight, and then took almost another hour and a half to finish the job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for logan, oh

CO 4.

CO 4. Job Checkin

Kitchen Exhaust Cleaning Cleaning KEC Semi-Annual - Main & Stove


CO 4.

CO 4. Job Checkin

Kitchen Exhaust Cleaning and Swap Pillow Cleaning KEC Every 2 Months - Main Hoods SWAPP As Needed - Grease Sock Replacement (Main)


CO 5.

CO 5. Job Checkin

Kitchen Exhaust Cleaning Cleaning KEC Semi-Annual - System 1 - Flat Top;Charbroiler;Fryer;Oven


Shawn M.

Shawn M. Job Checkin

Sprinkler Inspection FP Annual - Wet


Jamall S.

Jamall S. Job Checkin


CO 6.

CO 6. Job Checkin

Swap Pillow and Kitchen Exhaust Cleaning Cleaning Replace (2) 7" Driploc pillows KEC Quarterly SWAPP Quarterly - Replace (2) Small Pillows


CO 1.

CO 1. Job Checkin

Kitchen Exhaust Cleaning and Swap Pillow Cleaning KEC Semi Annual - Oven Hood KEC Every 2 Months - Main Hoods SWAPP As Needed - Grease Sock Replacement (Main)


Jamall S.

Jamall S. Job Checkin


CO 4.

CO 4. Job Checkin

Kitchen Exhaust Cleaning Cleaning KEC Annual - Dish Hood KEC Semi Annual- Main Kitchen


CO  7.

CO 7. Job Checkin

Kitchen Exhaust Cleaning Cleaning KEC Semi-Annual - Flat Top;Oven;Stove


CO  7.

CO 7. Job Checkin

KEC Quarterly SWAPP Quarterly - Replace (2) Small Pillows Kitchen Exhaust Cleaning and Swap Pillow Cleaning


CO 6.

CO 6. Job Checkin

Kitchen Exhaust Cleaning and Swap Pillow Cleaning KEC Every 2 Months - Main Hoods SWAPP As Needed - Grease Sock Replacement (Main)


CO 6.

CO 6. Job Checkin

Leaking Access Panel - Code Deficiency During your most recent kitchen exhaust cleaning service, our technicians noted that one or more of your access panels are leaking water and grease from your ductwork and need to be repaired per NFPA 96: 5.1.2 All seems, joints, and penetrations of the hood enclosure that direct and capture grease-laden vapors and exhaust gases shall have a liquid-tight continuous external weld to the hoods lower outermost perimeter Liquid-tight access panels are a crucial component of your exhaust system and required by NFPA. It is important to protect your staff and vendors from accidental fires. The proposal below is all-inclusive and includes all parts and labor. You can accept this proposal electronically or contact me directly. All quoted services/parts are installed/completed upon our next kitchen exhaust cleaning unless requested to be completed earlier. Due to constant price changes in the industry, the quoted price is only guaranteed for 14 days. Quo


CO 3.

CO 3. Job Checkin

Insufficient Rooftop Containment - Code Deficiency During your most recent kitchen exhaust cleaning service, our technicians noted that one or more of your rooftop exhaust fans need a grease containment system to prevent roof damage and fires. NFPA 96 8.1.2.3 Rooftop containment systems are a crucial component of your exhaust system and required by NFPA. It is important that your roof surface is free of grease to prevent fires and costly roof damage. The proposal below is all-inclusive and includes all parts (including 1st set of filters) and labor. These filters are swapped during each service at $59.50 per filter. You can accept this proposal electronically or contact me directly. All quoted services/parts are installed/completed upon our next kitchen exhaust cleaning unless requested to be completed earlier. Due to constant price changes in the industry, the quoted price is only guaranteed for 14 days. Quotes approved after the 14 days may be subject to a price increase. Thanks


CO 1.

CO 1. Job Checkin

Kitchen Exhaust Cleaning and Swap Pillow Cleaning KEC Annual - Dish Hood KEC Every 2 Months - Main Hoods SWAPP As Needed - Grease Sock Replacement (Main) Deficiency: Access panel leaks bad