Performed evaluation Downstairs unit condensor not functioning at arrival Delta 9 - failed TXV - system coil condition is low-medium grade Refrigerant status unknown due to TXV readings - may have estimate for refrigerant after job is performed Electrical repair performed to allow power for condensor performance Upstairs system delta 15-16 low on refrigerant - due to leak Due to similar conditions to downstairs unit - Future TXV may be diagnostic condition - medium Downstairs unit as primary for comfort advisor Comfort advisor scheduled Tuesday 04/29/25 9AM-12PM Reccomendations for new unit - April air kits - units do not have 4 inch base - soft start kits Flex - IAQ200 UV Systems left on cool at exit