1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Job Locations
for azle, tx


Map of Azle TX
Kellen M.

Kellen M.


Job Checkin

2019 3t closet upflow hp. Warranty status - all parts 2029. Filter replaced. Drain clear. Coil and blower inspected - clean. Blower capacitor within manufacturer tolerance. UV bulb outside of manufacturer kill rate - off. Slight biological growth present. TESP within manufacturer specifications. DeltaT 12° - ambient 81°. Start capacitor not working as intended. Compressor inrush amperage exceeds manufacturer specifications even with a start capacitor. Dual run capacitor below manufacturer tolerance - replaced. Electrical panel hot spot. Electrical inspection 6/30/25. Sat with homeowner with a pad and paper and shared all information. Homeowner agreed to the immediate fix for peace of mind and asked for emails of estimates to discuss with her son which was not able to be reached on my visit (homeowner attempted multiple times). Husband past away late 2024, this was his getaway home and current owner is deciding what to do with the house and is thinking about proper investment (m