2018 Amana airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Heat strips were functional and within manufacture range Blower motor and wheel were acceptable Blower wires have biological growth build up Evaporator coil was acceptable Condensate pan has biological growth build up Uv lamp was passed date to change 2018 Amana heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended lamp replacement or upgrading uv system to more efficient system. Customer agreed to upgrade uv system to uvc 200