Technicians arrived to customers home and introduced themselves aswell as handing home questioner sheet for homeowner to fill out. Technicians grabbed tools and started in furnace in attic. Technician noticed that blower wheel speed was off. Blower wheel looked in good condition, swapped air filter checked plenums all in good condition, evaporator coil in good condition, plenty of insulation aswell. Homeowner had a damper for return. Technicians then moved to outside condenser washed coils in and out, technician hooked gauges and refrigerant levels looked good, capacitor was in range, was a 45+5 was reading a 44+4, contactor looked In good condition. Technician took inrush amps came out to 92 amps. Technician wrote recommendations and suggested to disconnected damper for return side, aswell as compressor saver on condenser unit, homeowner agreed to get it done. Technician disconnected damper on return side and installed compressor saver on outside condenser unit. System overall workin