I did a two system super tuneup. Both systems are in the attic. Insulation is good. Both systems have water safeties furnace was running well. Deltas are nice. At the outdoor, there was a high in rush for the compressors. suggested hard start kits. Homeowner declined also suggested pant strips. Homeowner declined. Vacuum and washed out outdoor units and AC was running when I left.