Tech arrived at a membership tune-up. Upon inspection, the duel run capacitor was reading 0mfd. The contactor was in working condition. The condenser coils were damaged and restricted. The system did not appear to have Surge Protection. The blower was pulling high amperage. The Delta was within range. The drain was clear and bleach was poured. There was no drain safety. The indoor coil was rusted. The heating system reached complete ignition. The gas pipe is flexible and penetrates the cabinet. Also there is no easy way to shut off the gas at the unit. This is a safety concern. The customer was contacted via phone call and informed of recommendations. He may have an extra capacitor and will search for it. He is aware of the code item and recommendations. He will think about repairs/replacement closer to summer. The system was functioning upon departure.