For this evaluation the customer's downstairs furnace would ignite and then immediately shut off and repeat the process over and over again. Initially I did not have a fault code however after taking the door off and manually starting the system I had a fault indicating that the "Pressure switch stuck open". I pulled the tube off the pressure switch and inducer blew through it and used thermostat wiring to clear the nipple where some debris did come out. I took the actual inducer off cleaned out the inside and reassembled and the system ran like it should. Since the system was igniting but then shutting off I went ahead and replaced the flame sensor under warranty since that is the next stage after ignition. I left with the system running and heating and recommended the customers get a level 2 duct cleaning since they had their floors replaced and they stated there was a lot of dirt and dust that was kicked up during that process.