For this evaluation, The inside unit was Running so I immediately went to the outdoor unit, Upon inspecting, I noticed that the capacitor was out of tolerance Replace it with a new one and the compressor started working Connect to my gauges, Noticed That the low side was too low Change the filter, Went outside again, It was not going up in pressures Next step was to Leak detect, Found a leak in the evaporator coil Customer would like 2 solar attic fans installed Where the inside unit is located We will need to order a new evaporator coil, Also I will need a helper, Coordinate with Ryan To see who can help me Replenish with refrigerant until next visit to Replace evap coil