Justin  P.

Justin P.


Job Checkin

2018 Trane Airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil was acceptable Uv system is functional, lamp is past replacement date Antimicrobial pan treatment is functional 2018 Tran Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Uv system upgrade and compressor saver