!998 electric upflow closet. 2020 4t condenser - home warranty install. Expired manufacturers warranty. Poor filtration- 1 inch plus a large hole on the side of indoor unit allowing unfiltered air to pass through. Evaporator coil has major oil stains. Evaporator coil freezing. Evaporator coil dirty. Blower motor has major oil issues. Blower wheel is very dirty. Electric heatstrips have low ohms. Heavy biological growth. DeltaT 9° Condenser coils washed. Low and high voltage wires unprotected. Disconnect box has no saftey plate. Compressor inrush amperage exceeds manufacturers specifications. Fan side if dual run capacitor failing. Refrigerant charge below manufacturers tolerance. Shared all pertinent information with homeowner in detail. Agreed to a CA appointment 4/19/25 10@ confirmed with Rob G. System is not functioning properly. Consider upgrade air filtration and a heatpump for optimal performance.