1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Job Locations
for crowley, tx


Map of Crowley TX
garrett.young@acgenius.com

garrett.young@acgenius.com


Job Checkin

For this heating tune-up I inspected the customer's furnace as well as the condenser. For the most part everything was measuring within manufacturer specs and running well. The inducer motor was pulling .03 amps over the FLA, so it would be good to keep an eye on it. The dual run capacitor on the condenser was out of tolerance reading 20.6 MFD out of 70 so that will need to be changed before cooling season as the compressor wouldn't even kick on. I recommend it to the customer adding a hard start kit to the condenser to help with compressor amp draws on startup, as well as a duct cleaning and UV system to kill and prevent biological growth in the plenums and circulating around the home. Customer stated he would talk to his wife about recommendations.