For this super tune-up I inspected the customer's air handler and condenser. The dual run capacitor on the condenser is out of tolerance, measuring 30.8/45 MFD. The capacitor will need to be replaced soon to keep the system running especially as we move into warmer weather. I recommend adding a hard start kit as well, as the LRA is right at the max Amp draw, and will start to damage the internals of the compressor. The customer had another company come out and do a duct cleaning for $99 however she still has dust coming out of her vents when the system is running, a thorough duct cleaning performed by us would be highly recommended as well. The attic only has an R-Value of about 13.5 or 5". She needs a lot more insulation, as she stated her electric bills are really high and insulation is the number one thing she can add to her home to lower energy consumption. Homeowner would like to have an electrician come look at her electrical panel since it is from 1972, and she has been having