2015 gas closet. Expired manufacturers warranty. Many parts have been replaced. Blower wheel dirty. Evaporator coil dirty. Evaporator coil has detectable leaks. Evaporator coil has rust. Compressor is amping high even with a start capacitor. Refrigerant levels are slightly below manufacturers specifications. The boards were taken off the louvers of the door where the furnace sits, (I didn't realize until she mentioned it) since then the homeowner feels gusts of wind in the hall and when she looked up noticed she can see her attic and had concerns about airflow. The flue pipe is touching the supply plenum but due to the metallic material of the plenum, it passes code. Minimum insulation in attic. Uv bulb is not functional. The light socket to the gas furnace circuit is compromised (I showed her and she will have her electrical friend look at it). All things considered, due to the age, performance and saftey of the system, the homeowner agreed to a CA appointment 4/5/25 @3p to dis