2011 3t duel fuel closet upflow. Expired manufacturers warranty. Filter replaced. Blower dirty. Evaporator coils detected leaks. DeltaT low. Refrigerant charge blow tolerance. Inrush amperage on compressor is exceeding manufacturers specifications. Vapor line insulation compromised. Condenser fan motor FLA is below manufacturers specifications. I sat with homeowner and shared all evidences with photos and video. Homeowner is elderly and claims to have a trust her son who lives in another state controls. I offered to speak to son but she declined. The roof blew off at the beginning of March and the homeowner was overwhelmed. Declined all potential options to restore and replace. I've explained system performance issues and saftey hazards. Homeowner fully understands the consequences of not doing anything. If a 45 is to be ran, please send me. System functioning but heavily diminishing in performance.