Upstairs Lennox Changed customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil has slight biological growth beginning to grow Dual run cap is within manufacture range Primary electrical unit was acceptable Refrigeratant levels were within range at this time Washed condenser coils Downstairs Trane Could not change filter due to filter being too big for filter box Blower motor and wheel were acceptable Evaporator coil is heavily rusted and has heavy biological growth build up Dual Run cap is weak Primary electrical unit have heavy pitting Refrigeratant levels are showing slightly low at this time Washed condenser coils from inside out Recommended UV System for all 3 systems, drain switch for Trane system, dual run cap for Trane, primary electrical unit for Trane, compressor saver for both systems