Upon technicians arrival tech found the door to the blower off the unit 2 feet away tech looked inside and found two of the bl9wers bolt for the bracket off and in the furnace cabinet tech put them back in and jumped the unit tech found that one of the bolts had came out again tech found that the blower cage is striped and needs to be replaced tech also found that the blower wheel was unbalanced Causing it to strip the cage tech found that the blower motor is over amping due to being unbalanced tech also found that the gas line into the furnace didn't have a sediment trap tech looked at the heat exchanger and didn't find any cracks Techs recommendations on the fix is replacing the blower motor, cage, wheel and fixing the gas line with the system being 9 years old tech recommends in investing into having ca come out due to age and getting warranty on the system as well as getting gas line up to code tech will call Monday morning to talk with home owner this system is down