Performed evaluation Filters not provided for replacement - homeowner will replace filters Upon arrival both systems operational Washed condensors and tightened connections Upstairs 19 Delta downstairs 15 Delta Primary drain lines holding water and water has medium blockage on lines Reccomended drain clear and reconfigure of trap design from negative pressure to positive pressure Saftey switch was out of primary line hanging on side - left as is due to the unit being able to turn off once re inserted Homeowners are aware water drops are being thrown due to pressure Reccomended refrigerant (minor) for downstairs system Reccomended soft start kits for both systems due to having high amperage start Reccomended home and budget protection plan Homeowners will contact original installer and may give us a call back for reccomended work Systems left on cool at exit