Performed evaluation Upon arrival upstairs system was functioning 13 Delta - refrigerant loss estimate around 1/2 Indoor blower motor has loose rod/bearings - audible pressure fluctuating from motor Reccomended primary electrical control unit replacement- electrical burns around contacts Reccomended soft start kit Reccomended refrigerant Reccomended Schrader valves on high and low side Reccomended drain saftey and drain reconfigure Reccomended home and budget plan Due to original homeowner technician introducing incorrect refrigerant into system and next technician putting correct refrigerant- compressor may have been damaged internally from the timespan - may need future replacement Provided future estimate for homeowners on possible repairs Outdoor blower motor TXV metering device Filter Dryer New estimated refrigerant This is for full refurbished potential After performed main concerns of operation would be indoor/outdoor coils Master bedroom (functioning from other system) doe