Jeffrey  B.

Jeffrey B.


Job Checkin

Arrived at location and spoke with home owner. Inspected indoor unit. Electrical connections tight. Blower wheel clean. Blower capacitor out of spec. Replaced under warranty. Coil clean and in good condition. Temperature delta within acceptable range. Drain clear. Flood detector active. UV bulb due for replacement. Recommended replacement. Replaced with bulb supplied by home owner. Bulb defective. Instructed home owner on bulb replacement and handling procedures for when her new bulb arrives. Inspected outdoor unit. Electrical connections tight. Capacitor in spec. Fan and compressor Amp draw good. Refrigerant charge good. Coil in good condition. Discussed benefits and need of surge protection. Recommended either unit surge protection or home panel surge protection. Home owner agreed to unit surge protection. Unit surge protector installed and active. Discussed benefits of adding compressor saver to outdoor unit. Home owner agreed. Compressor saver installed.