Tech arrived for a first year tuneup and HTU. New system- the capacitor was within specs. The contactor was in working condition. The coils were clean. The Delta was at acceptable levels. The system did not appear to have Surge Protection. The filter was relatively clean. The drain system was clear and bleach was poured. The heating system reached complete ignition. The UV bulb was not working. Old system- The capacitor was out of tolerance and was replaced. The contactor was scorched and was audibly buzzing. The fan motor was rusted and vibrating. The compressor was pulling high amperage on startup. The system did not appear to have Surge Protection. The filter was relatively clean. The blower area and coil was a little dirty. The heating system reached complete ignition however the flame sensor was severely scorched. This item was replaced today. The drain system was clear at this time. There was no drain safety observed. A drain form was filed. The Delta and refrigerant was at ac