Service fee waived per Brian H. AC repair. Arrived to no cool. Indoor blower would turn on but outdoor condenser would not. Discovered the breaker to the outdoor unit in the main panel had tripped. Reset breaker and it tripped again immediately. Meg ohm tested to compressor to find that it had a short to ground. Compressor has failed and needs to be replaced.