Job Checkin

2011 Goodman airhandler Checked and tightened all electrical connections Customer did not have extra filters for changing Blower motor and wheel were heavily compacted with dust and biological growth Evaporator coil was heavily compacted with dust and dirt Drain was clear and draining 2007 Carrier heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended Blower cleaning, coil cleaning and uv light